Measurement of VLE Data by Using an Experimental Installation with Automatic Control: Modeling of Binary Systems of Methyl Acetate or Ethyl Acetate with n-Heptane or 2,2,4-Trimethylpentane at Both 0.1 and 1.5 MPa Susial Badajoz, P.; García-Vera, D.; Marrero-Pérez, A.; Padrón-Guerra, N.; Mujica-González, T.; Journal of Chemical & Engineering Data 2019, 64, 5591-5608
Data
P = 1500 kPa
x (mol mol-1) Tbp (K)
0 498.65
0.217 469.7
0.288 462.69
0.316 460.28
0.372 455.89
0.401 454.18
0.428 452.6
0.491 449.35
0.521 448.01
0.558 446.83
0.596 445.54
0.019 495.85
0.624 444.56
0.646 443.62
0.680 442.61
0.738 440.9
0.769 440.31
0.796 439.62
0.827 438.81
0.855 438.34
0.885 437.83
0.910 437.29
0.035 493.05
0.936 436.97
0.959 436.56
0.977 436.25
0.992 436.17
1 436.08
0.050 490.65
0.076 487.35
0.093 484.55
0.119 481.25
0.148 477.25
0.175 474.25
2722; methyl ethanoate + heptane; 00005:00022