Critical Parameters and Vapor Pressure Measurements of Potential Replacements for Chlorofluorocarbons-Four Hydrofluoroketones and a Hydrofluoroamine Otake, K.; Yasumoto, M.; Yamada, Y.; Murata, J.; Urata, S.; Journal of Chemical & Engineering Data 2003, 48, 1380-1383
- Journal: Journal of Chemical & Engineering Data
- Sample Quantity(ies): Vapor pressure
- Methodology: CCELL:UFactor:2
- Phase(s): Liquid
- Substances:
Data
| T (K) | P (kPa) |
| 302.45 | 25.1 |
| 412.86 | 797.0 |
| 422.87 | 976.9 |
| 432.93 | 1190.2 |
| 442.96 | 1434.6 |
| 452.99 | 1723.0 |
| 463.02 | 2043.2 |
| 468.04 | 2225.9 |
| 473.05 | 2422.3 |
| 475.51 | 2515.0 |
| 475.62 | 2520.5 |
| 314.15 | 41.4 |
| 323.18 | 59.6 |
| 352.69 | 166.6 |
| 362.68 | 224.3 |
| 372.77 | 302.4 |
| 382.79 | 395.0 |
| 392.82 | 503.1 |
| 402.82 | 641.5 |
17656; 1,1,1,2,2,3,3-heptafluoropentan-4-one; 03509