Measurement of heat capacities of ionic liquids by differential scanning calorimetry Diedrichs, A.; Gmehling, J.; Fluid Phase Equilibria 2006, 244, 68-77
- Journal: Fluid Phase Equilibria
- Sample Quantity(ies): Molar heat capacity at constant pressure
- Methodology: modulated-temperature differential scanning calorimetry MDSC
- Phase(s): Liquid
- Substances:
Data
| T (K) | Cp (J mol-1 K-1) |
| 328.15 | 599.0 |
| 373.15 | 628.0 |
| 378.15 | 631.0 |
| 383.15 | 635.0 |
| 388.15 | 637.0 |
| 393.15 | 640.0 |
| 398.15 | 642.0 |
| 403.15 | 645.0 |
| 408.15 | 648.0 |
| 413.15 | 651.0 |
| 333.15 | 603.0 |
| 338.15 | 606.0 |
| 343.15 | 609.0 |
| 348.15 | 612.0 |
| 353.15 | 616.0 |
| 358.15 | 619.0 |
| 363.15 | 622.0 |
| 368.15 | 625.0 |
1385; 1-octyl-3-methylimidazolium trifluoromethanesulfonate; 00483