Measurement of heat capacities of ionic liquids by differential scanning calorimetry Diedrichs, A.; Gmehling, J.; Fluid Phase Equilibria 2006, 244, 68-77
- Journal: Fluid Phase Equilibria
- Sample Quantity(ies): Molar heat capacity at constant pressure
- Methodology: modulated-temperature differential scanning calorimetry MDSC
- Phase(s): Liquid
- Substances:
Data
| T (K) | Cp (J mol-1 K-1) |
| 323.15 | 680.0 |
| 368.15 | 705.0 |
| 373.15 | 706.0 |
| 378.15 | 709.0 |
| 383.15 | 711.0 |
| 388.15 | 714.0 |
| 393.15 | 716.0 |
| 398.15 | 718.0 |
| 403.15 | 720.0 |
| 408.15 | 723.0 |
| 413.15 | 723.0 |
| 328.15 | 682.0 |
| 333.15 | 685.0 |
| 338.15 | 688.0 |
| 343.15 | 689.0 |
| 348.15 | 693.0 |
| 353.15 | 695.0 |
| 358.15 | 698.0 |
| 363.15 | 701.0 |
259; 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide; 00129