Viscosity-induced errors in the density determination of room temperature ionic liquids using vibrating tube densitometry Sanmamed, Y.; González-Salgado, D.; Troncoso, J.; Cerdeiriña, C.; Romaní­, L.; Fluid Phase Equilibria 2007, 252, 96-102
Data
P = 101.325 kPa
T (K) η (Pa s)
288.15 0.3157
293.15 0.2328
298.15 0.1741
303.15 0.1321
308.15 0.103
313.15 0.0817
318.15 0.0659
323.15 0.0539
5447; 1-hexyl-3-methylimidazolium tetrafluoroborate; 00848