Vapour-liquid equilibrium (VLE) for the systems furan + n-hexane and furan + toluene. Measurements, data treatment and modeling using molecular models Nala, M.; Auger, E.; Gedik, I.; Ferrando, N.; Dicko, M.; Paricaud, P.; Volle, F.; Passarello, J.P.; de Hemptinne, J.C.; Tobaly, P.; Stringari, P.; Coquelet, C.; Ramjugernath, D.; Naidoo, P.; Lugo, R.; Fluid Phase Equilibria 2013, 337, 234-245
- Journal: Fluid Phase Equilibria
- Sample Quantity(ies): Boiling point at pressure
- Methodology: Ebulliometric method (Recirculating still)
- Phase(s): Liquid
- Substances:
Data
| x (mol mol-1) | Tbp (K) |
| 0.028 | 338.43 |
| 0.567 | 310.26 |
| 0.639 | 309.06 |
| 0.715 | 307.66 |
| 0.813 | 306.26 |
| 0.856 | 305.69 |
| 0.905 | 305.36 |
| 0.968 | 304.94 |
| 0.991 | 304.72 |
| 0.049 | 335.98 |
| 0.078 | 332.85 |
| 0.117 | 329.37 |
| 0.172 | 325.05 |
| 0.267 | 319.59 |
| 0.349 | 316.37 |
| 0.424 | 313.94 |
| 0.493 | 311.81 |
32420; furan + hexane; 00002:02743