Data
| T (K) | P (kPa) | ρ (kg m-3) |
| 283.15 | 100 | 738.2 |
| 298.15 | 5000 | 730.9 |
| 298.15 | 10000 | 734.5 |
| 298.15 | 30000 | 747.5 |
| 298.15 | 50000 | 758.8 |
| 298.15 | 70000 | 768.6 |
| 323.15 | 100 | 708.1 |
| 323.15 | 1000 | 708.5 |
| 323.15 | 5000 | 712.0 |
| 323.15 | 10000 | 716.2 |
| 323.15 | 30000 | 731.0 |
| 283.15 | 1000 | 738.6 |
| 323.15 | 50000 | 743.5 |
| 323.15 | 70000 | 754.3 |
| 333.15 | 100 | 700.4 |
| 333.15 | 1000 | 700.9 |
| 333.15 | 5000 | 704.7 |
| 333.15 | 10000 | 709.2 |
| 333.15 | 30000 | 724.7 |
| 333.15 | 50000 | 737.7 |
| 333.15 | 70000 | 749.0 |
| 348.15 | 100 | 688.7 |
| 283.15 | 5000 | 741.6 |
| 348.15 | 1000 | 689.3 |
| 348.15 | 5000 | 693.4 |
| 348.15 | 10000 | 698.3 |
| 348.15 | 30000 | 715.1 |
| 348.15 | 50000 | 728.9 |
| 348.15 | 70000 | 740.8 |
| 373.15 | 100 | 668.0 |
| 373.15 | 1000 | 669.7 |
| 373.15 | 5000 | 674.6 |
| 373.15 | 10000 | 680.3 |
| 283.15 | 10000 | 744.9 |
| 373.15 | 30000 | 699.5 |
| 373.15 | 50000 | 714.8 |
| 373.15 | 70000 | 727.7 |
| 398.15 | 100 | 647.5 |
| 398.15 | 1000 | 648.5 |
| 398.15 | 5000 | 654.1 |
| 398.15 | 10000 | 660.8 |
| 398.15 | 30000 | 682.6 |
| 398.15 | 50000 | 699.5 |
| 398.15 | 70000 | 713.5 |
| 283.15 | 30000 | 757.1 |
| 283.15 | 50000 | 767.7 |
| 283.15 | 70000 | 777.1 |
| 298.15 | 100 | 727.2 |
| 298.15 | 1000 | 727.8 |
713; n-decane; 00288