Automated densimetric system: Measurements and uncertainties for compressed fluids Segovia, J.J.; Fandiño, O.; López, E.R.; Lugo, L.; Carmen MartÃn, M.; Fernández, J.; The Journal of Chemical Thermodynamics 2009, 41, 632-638
- Journal: The Journal of Chemical Thermodynamics
- Sample Quantity(ies): Mass density
- Methodology: Vibrating tube method
- Phase(s): Liquid
- Substances:
Data
| T (K) | P (kPa) | ρ (kg m-3) |
| 283.15 | 100 | 1026.6 |
| 298.15 | 5000 | 1018.0 |
| 298.15 | 10000 | 1021.1 |
| 298.15 | 30000 | 1032.6 |
| 298.15 | 50000 | 1043.0 |
| 298.15 | 70000 | 1052.3 |
| 323.15 | 100 | 994.6 |
| 323.15 | 1000 | 995.2 |
| 323.15 | 5000 | 998.1 |
| 323.15 | 10000 | 1001.6 |
| 323.15 | 30000 | 1014.3 |
| 283.15 | 1000 | 1027.2 |
| 323.15 | 50000 | 1025.6 |
| 323.15 | 70000 | 1035.8 |
| 333.15 | 100 | 986.7 |
| 333.15 | 1000 | 987.3 |
| 333.15 | 5000 | 990.4 |
| 333.15 | 10000 | 994.0 |
| 333.15 | 30000 | 1007.2 |
| 333.15 | 50000 | 1018.9 |
| 333.15 | 70000 | 1029.4 |
| 348.15 | 100 | 974.7 |
| 283.15 | 5000 | 1029.7 |
| 348.15 | 1000 | 975.4 |
| 348.15 | 5000 | 978.6 |
| 348.15 | 10000 | 982.4 |
| 348.15 | 30000 | 996.5 |
| 348.15 | 50000 | 1008.8 |
| 348.15 | 70000 | 1019.9 |
| 373.15 | 100 | 953.7 |
| 373.15 | 1000 | 955.4 |
| 373.15 | 5000 | 959.1 |
| 373.15 | 10000 | 963.4 |
| 283.15 | 10000 | 1032.5 |
| 373.15 | 30000 | 978.9 |
| 373.15 | 50000 | 992.4 |
| 373.15 | 70000 | 1004.3 |
| 398.15 | 100 | 934.1 |
| 398.15 | 1000 | 935.0 |
| 398.15 | 5000 | 938.9 |
| 398.15 | 10000 | 943.7 |
| 398.15 | 30000 | 960.8 |
| 398.15 | 50000 | 975.4 |
| 398.15 | 70000 | 988.3 |
| 283.15 | 30000 | 1043.3 |
| 283.15 | 50000 | 1053.1 |
| 283.15 | 70000 | 1061.9 |
| 298.15 | 100 | 1014.7 |
| 298.15 | 1000 | 1015.3 |
14899; pentaerythritol tetrapentanoate; 00084